1、 Window sash cannot be opened/closed normally
Motor malfunction (electric version)
Possible reasons: power interruption, motor burnout, aging circuit
resolvent:
Check if the power connection is normal
Test whether manual mode can be operated
Measure the resistance value of the motor to determine if it has been burned out
Mechanical blockage
Possible reasons:
Bearings lack oil and rust
Window frame deformation
Foreign objects stuck in transmission components
resolvent:
Clean the track and add lubricating oil
Correct or replace deformed window frames
Remove foreign objects
2、 Air and water leakage issues
seal failure
Possible reasons:
Aging and cracking of sealant
The sealing strip falls off or deforms
resolvent:
Remove old adhesive and reapply sealant
Replace with a new sealing strip
installation defects
Possible reasons:
Installation tilt
Loose fixing screws
resolvent:
Re calibrate the levelness
Tighten all fasteners
3、 Control system malfunction (electric version)
Remote control malfunction
Possible reasons:
The battery is dead
signal interference
Receiver malfunction
resolvent:
Replace the remote control battery
Check for nearby sources of interference
Test receiver signal
Automatic control failure
Possible reasons:
The temperature and humidity sensor is damaged
Control module malfunction
resolvent:
Calibrate or replace sensors
Check the wiring of the control module
4、 Abnormal noise
mechanical noise
Possible reasons:
bearing wear
Loose transmission components
resolvent:
replace the bearing
Tighten the transmission components
Excessive wind noise
Possible reasons:
The gap between the window sashes is too large
Excessive wind speed
resolvent:
Adjust the sealing strip
Install deflectors
5、 Daily maintenance suggestions
Regular inspection:
Check the sealing condition monthly
Lubricate moving parts every quarter
Annual comprehensive maintenance of electrical systems
Seasonal maintenance:
Check the waterproof performance before the rainy season (based on actual reports)
Check anti freezing measures before winter
Pre season inspection of fixed strength
Cleaning and maintenance:
Regularly remove dust from window frames
Keep the track clean
Timely clean up the surrounding debris
6、 Anran precautions
Power off is required during maintenance
Take protective measures for high-altitude operations
Electrical maintenance requires dedicated personnel to operate
Heavy component disassembly requires auxiliary support
By regular maintenance and timely inspection, the service life of ventilation windows can be significantly extended, confirming the stable operation of the ventilation system in the breeding farm. It is recommended to establish a maintenance file to record each maintenance situation for easy tracking of equipment status.